Marine Fire Safety: Why the BHH-31A Is Trusted at Sea

Fire at sea is unforgiving. The BHH-31A is type-approved by DNV and Lloyd's Register for marine use — here is what that approval means in practice.

18 June 2026·By Autronica Parts Engineering Team
Back to all articles

Why marine approvals exist

Fire on a ship is not the same as fire in a building. Crew response options are limited, escape routes are narrow, and help is hours or days away. SOLAS Chapter II-1 and II-2 therefore require that detectors installed on board be type-approved by a recognized classification society. The BHH-31A carries type-approval from DNV and Lloyd's Register and falls under the Marine Equipment Directive (MED) for vessels flying EU flags.

What type approval tests cover

DNV and Lloyd's Register approval is not a re-run of EN54-7. It adds:

  • Vibration and shock testing that simulates ship machinery and sea motion.
  • Inclination testing — the detector must alarm at angles up to 22.5°.
  • EMC compatibility with shipboard power and radio equipment.
  • Corrosion resistance — salt-spray exposure to mimic marine atmosphere.
  • Humidity and temperature cycling beyond the standard building range.

The BHH-31A passes all of these and is listed for use in accommodation, service, and control spaces.

Where the BHH-31A is installed on board

  • Cabins and corridors: optical detection gives the earliest warning to sleeping crew and passengers.
  • Control rooms and ECR: fast, addressable detection with low standby current — important for ships that run on battery-backed loops.
  • Galleys and pantries: only as part of a mixed system, paired with heat detection as SOLAS requires.

Sourcing approved detectors

Not every version of every detector carries marine approval — only the specific part numbers listed on the society's certificate. We supply the genuine BHH-31A with traceable part numbers, certificate references, and documentation packs that pass surveyor inspection. If your class society surveyor needs a particular document, ask us before shipment and we will include it.

Need help with your project?

Talk to our team about specifying the right BHH-31A detector for your application.