What is an optical smoke detector?
An optical smoke detector uses a light source — typically an infrared LED — and a photodiode sensor positioned away from the light beam. In clean air, the light does not reach the sensor. When smoke particles enter the chamber, they scatter the light toward the sensor, which triggers the alarm. This light-scattering principle makes optical detectors especially sensitive to the visible smoke produced by smoldering fires — the kind of fire that develops slowly but can release toxic gases long before flames appear.
The Autronica BHH-31A applies this technology inside a compact, addressable detector head designed for the Autronica AutroSafe and BS-420 fire alarm panels.
Where the BHH-31A fits
The BHH-31A is the right choice when early detection of smoldering fires matters more than fast flame detection. Typical applications include:
- Hotel guest rooms and corridors
- Office buildings and meeting rooms
- Hospital wards and patient areas
- Marine accommodation spaces and engine control rooms
- Schools and public buildings
For environments with high dust, steam, or aerosol concentrations, consider pairing the BHH-31A with a multi-sensor or heat detector — or contact our team for guidance on detector placement.
Why EN54-7 certification matters
EN54-7 is the European standard that defines performance requirements for point-type smoke detectors using scattered light. Certification under EN54-7 means the BHH-31A has been independently tested for:
- Sensitivity across a defined range of smoke densities
- Stability — no false alarms under defined environmental conditions
- Response time within the limits the standard sets
- Durability of components over the certified operating temperature and humidity range
Specifying only EN54-7 certified detectors is, in many jurisdictions, a legal or insurance requirement for commercial buildings and marine vessels.
Addressable detection and system integration
The BHH-31A is an addressable detector: the panel identifies each detector by a unique address, so responders know the precise location of an alarm. It mounts on the standard Autronica detector base and is automatically recognized by AutroSafe and BS-420 loops. This makes commissioning, expansion, and replacement straightforward.
Sizing an order
For new installations, allow one BHH-31A per detection zone, spaced according to the local fire code (typically one detector per 50–60 m² in nonsmoking office areas, with reduced spacing in corridors). For replacement work, the BHH-31A is a drop-in substitute for legacy Autronica optical heads on the same base, with panel software versions supporting addressable optical detectors.
If you need help sizing an order for a specific project, send us the floor plans or a detector schedule at sale@autronica-parts.com and we will return a priced proposal — typically within one business day.